Attribute | Value |
---|---|
Deif | 1114130002c |
Check Synchroscope | Deif |
Kohsel | 627 |
Part Number | 1114130002c |
Model | Check Synchroscope |
Order No. | 30/12-3365 |
Voltage | 110-220V |
Weight | 680 Gm |
Condition | Used 1 Pcs |
Ref No | 57589 |
What Is a Synchroscope?
A synchroscope is a device used to measure the phase angle and frequency difference between two power sources. This ensures that the generator being synchronized matches the grid’s electrical characteristics, enabling a seamless connection. The Deif 1114130002c is a high-precision synchroscope designed for modern power systems.
Key Features of the Deif 1114130002c
High Accuracy: Offers precise phase angle and frequency readings.
User-Friendly Interface: Equipped with an intuitive display for real-time monitoring.
Robust Design: Built for durability in demanding environments.
Multiple Connection Options: Suitable for a wide range of power systems.
Step-by-Step Guide to Checking the Synchroscope
Inspect the Physical Condition
Before using the synchroscope, inspect it for any visible damage or wear. Check connectors and terminals to ensure they are secure and free of corrosion.
Power Up the Synchroscope
Connect it to a known good power source, and observe it for successful startup. Check the display for any self-diagnostics.
Verify Calibration
Periodic calibration checks will ensure the synchroscope accurately reads data. A comparison reference device, or manufacturer-calibration procedure may be used.
Connect to Generator and Grid
Use the right cables to connect to the synchroscope to the generator’s output terminals and the grid. Make sure the connections are tight and according to the instruction manual.
Watch the Indicators
- The frequency of the generator must match that of the grid.
- The phase angle difference must approach the value of zero.
- The needle of the synchroscope or any digital indicator, will start to move slowly toward the “in-phase” position.
Synchronize the Generator
Once the readings show synchronization, connect the generator. Always observe safety precautions in this process.
Test the System
After synchronization, monitor the system to ensure that it is stable. Any anomalies must be addressed immediately.
Why the Deif 1114130002c Synchroscope Matters?
The Deif 1114130002c synchroscope simplifies the complex process of generator synchronization, making it a reliable tool for power system operators. Its precision and robust design ensure safe and efficient operation, reducing downtime and enhancing system stability.