Abb Sadt 50 Mp 33H-and Sadt 300-boards
interpreting fault-led’s on sadt 51 mn 33h- and sadt 300-boards
sadt 51 mn 33h
fault message: fl02
fault description:
neg. side chopper under voltage
neg. side chopper over voltage
negative side dc over voltage
sadt 300
fault message: fl04
fault description:
fault generated by sadt 51 mn 33h
negative side dc over voltage
chopper module malfunction